The challenge.
The proposed 30 × 13 ft lean-to porch was shown next to an existing two-story residence. The drawing notes require the existing concrete patio slab thickness and suitability to be verified before posts are anchored.
The structural drawing scope needed to communicate the proposed roof, supports, framing and important attachment details without assuming existing conditions had already been verified.
Our approach.
The site plan identified where the new covered porch would be located relative to the home and available property information.
The structural plans show 6 × 6 in. pressure-treated posts, paired 2 × 12 in. beams, 2 × 10 in. rafters at 16 in. on center and a 2 × 12 in. ledger attached to verified structural framing.
The detail sheets specify Simpson ABU66Z post bases or approved equivalents, uplift connectors and ledger fastening requirements. Elevations illustrate a 3:12 roof pitch with asphalt-shingle roofing.
The outcome.
The supplied file contains seven drawing sheets documenting site placement, structural framing, elevations, sections and connection details.
The selected drawing excerpts document the proposed work. Final permit issuance and completed construction have not been independently verified.